BIFACIAL ENERGY YIELD GAIN OF UP TO 20 %
Bifacial Q.ANTUM solar cells make efficient use of light shining
on the module rear-side for radically improved LCOE.
LOW ELECTRICITY GENERATION COSTS
Q.ANTUM DUO Z combines cutting edge cell separation and innovative
wiring with Q.ANTUM Technology for higher yield per surface area, lower
BOS costs, higher power classes, and an efficiency rate of up to 21.5 %.
INNOVATIVE ALL-WEATHER TECHNOLOGY
Optimal yields, whatever the weather with
excellent low-light and temperature behavior.
ENDURING HIGH PERFORMANCE
Long-term yield security with Anti LID and Anti PID Technology
1
,
Hot-Spot Protect and Traceable Quality Tra.Q™.
FRAME FOR VERSATILE MOUNTING OPTIONS
High-tech aluminum alloy frame protects from damage, enables use
of a wide range of mounting structures and is certified regarding IEC
for high snow (5400 Pa) and wind loads (2400 Pa).
A RELIABLE INVESTMENT
Double glass module design enables extended lifetime with 12-year
product warranty and improved 30-year performance warranty
2
.
1
APT test conditions according to IEC / TS 62804-1:2015 method B (−1500 V, 168 h) including post treatment
according to IEC 61215-1-1 Ed. 2.0 (CD)
2
See data sheet on rear for further information.
THE IDEAL SOLUTION FOR:
Ground-mounted
solar power plants
Q.PEAK DUO XL-G11.3 / BFG
570-585
BIFACIAL DOUBLE GLASS MODULE
WITH EXCELLENT RELIABILITY
AND ADDITIONAL YIELD
α
[% / K] +0.04
β
[% / K] −0.27
γ
[% / K] 0.34 NMOT [°F] 108 ± 5.4 (42± 3 °C)
[V] 1500 Class II
[A DC] 25 TYPE 29
4
[lbs/ft
2
] 75 (3600 Pa) / 33 (1600 Pa)
−40 °F up to +185 °F
(−40 °C up to +85 °C)
[lbs/ft
2
] 113 (5400 Pa) / 50 (2400 Pa)
3
See Installation Manual
4
New Type is similar to Type 3 but with metallic frame
Certified
UL 61730
570 575 580 585
BSTC* BSTC* BSTC* BSTC*
[W] 570 623.5 575 629.0 580 634.4 585 639.9
[A] 13.50 14.77 13.52 14.80 13.55 14.83 13.57 14.86
[V] 53.50 53.69 53.53 53.72 53.56 53.75 53.59 53.78
[A] 12.83 14.03 12.87 14.09 12.92 14.14 12.97 14.19
[V] 44.44 44.43 44.66 44.65 44.88 44.87 45.10 45.09
[%] ≥ 20.8 ≥ 22.8 ≥ 21.0 ≥ 23.0 ≥ 21.2 23.2 ≥ 21.4 23.4
[W] 429.1 432.9 436.6 440.4
[A] 10.87 10.89 10.91 10.93
[V] 50.60 50.63 50.66 50.68
[A] 10.09 10.14 10.18 10.22
[V] 42.51 42.71 42.89 43.08
Hanwha Q CELLS America Inc.
400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL [email protected] | WEB www.q-cells.us
MECHANICAL SPECIFICATION
Format
95.1 in × 44.7 in × 1.38 in (including frame)
(2416 mm × 1134 mm × 35 mm)
Weight 75.8 lbs (34.4 kg)
Front Cover 0.08 in (2.0 mm) thermally pre-stressed glass with
anti-reflection technology
Back Cover 0.08 in (2.0 mm) semi-tempered glass
Frame Anodized aluminum
Cell 6 × 26 monocrystalline Q.ANTUM solar half cells
Junction Box 2.09-3.98 in × 1.26-2.36 in × 0.59-0.71 in
(53-101 mm × 32-60 mm × 15-18 mm), IP67, with bypass diodes
Cable 4 mm² Solar cable; (+) ≥ 29.5 in (750 mm), (−) ≥ 13.8 in (350 mm)
Connector Stäubli MC4-Evo2, Hanwha Q CELLS HQC4, IP68
Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use
of this product.
Specifications subject to technical changes © Q CELLS Q.PEAK DUO XL-G11. 3 / BFG_ 570- 585 _2021-0 5_Rev01_NA
Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE
At least 98 % of nominal power during
first year. Thereafter max. 0.45 %
degradation per year. At least 94 %
of nominal power up to 10 years. At
least 85 % of nominal power up to
30years.
All data within measurement toleranc-
es. Full warranties in accordance with
the warranty terms of the Q CELLS
sales organisation of your respective
country.
Typical module performance under low irradiance conditions in
comparison to STC conditions (25 °C, 1000 W/m²)
TEMPERATURE COEFFICIENTS
Temperature Coefficient of I
SC
Temperature Coefficient of V
OC
Temperature Coefficient of P
MPP
Nominal Module Operating Temperature
PROPERTIES FOR SYSTEM DESIGN
Maximum System Voltage V
SYS
PV module classification
Maximum Series Fuse Rating Fire Rating based on ANSI / UL 61730
Max. Design Load, Push / Pull
3
Permitted Module Temperature
on Continuous Duty
Max. Test Load, Push / Pull
3
44.7"
(1134 mm)
55.1" (1400 mm)
95.1" (2416 mm)
1.38" (35 mm)
4 × Mounting slots (DETAIL A)
8 × Drainage holes
0.12 × 0.24
" (3 × 6 mm)
Frame
43.0
"
(1092 mm)
NA
Label
4 × Grounding holes,
Ø 0.18
" (4.5 mm)
15.7" (400 mm)
8 × Mounting slots system Tracker (DETAIL B)
DETAIL A
0.63" (16 mm)
0.33
" (8.5 mm)
0.82" (21 mm)
DETAIL B
0.39" (10 mm)
0.28" (7 mm)
0.86" (22 mm)
42.1"
(1090 mm)
31.2" (790 mm)
13.8" (350 mm)
≥ 29.5" (750 mm)
20.0" (508 mm)
4 × Drainage holes
0.11 × 0.24
" (2.8 × 6 mm)
4 × Drainage holes
0.12 × 0.24
" (3 × 6 mm)
QUALIFICATIONS AND CERTIFICATES
UL 61730, CE-compliant,
IEC 61215:2016,
IEC 61730:2016,
U.S. Patent No. 9,893,215
(solar cells)
ELECTRICAL CHARACTERISTICS
POWER CLASS
MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC
1
AND BSTC
1
(POWER TOLERANCE +5 W / −0 W)
Minimum
Power at MPP
1
P
MPP
Short Circuit Current
1
I
SC
Open Circuit Voltage
1
V
OC
Current at MPP I
MPP
Voltage at MPP V
MPP
Efficiency
1
η
Bifaciality of P
MPP
and I
SC
70 % ± 5 % • Bifaciality given for rear side irradiation on top of STC (front side) • According to IEC 60904-1-2
1
Measurement tolerances P
MPP
± 3 %; I
SC
, V
OC
± 5 % at STC: 1000 W/m²; *at BSTC: 1000 W/m² + φ × 135 W/m², φ = 70 % ± 5 %, 25 ± 2 °C, AM 1.5 according to IEC 60904-3
MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT
2
Minimum
Power at MPP P
MPP
Short Circuit Current I
SC
Open Circuit Voltage V
OC
Current at MPP I
MPP
Voltage at MPP
V
MPP
2
800 W/m², NMOT, spectrum AM 1.5
RELATIVE EFFICIENCY
COMPARED TO NOMINAL POWER [%]
100
95
90
85
80
75
155 25200 10
YEARS
98
Q CELLS
Industry standard for tiered warranties
*
Industry standard for linear warranties
*
*
Standard terms of guarantee for the 10 PV companies
with the highest production capacity in 2014 (as at: September 2014)
30
RELATIVE EFFICIENCY [%]
IRRADIANCE [W/m²]
200 400 600 800 1000
110
100
90
80
1200